{"created":"2023-05-15T12:35:55.320399+00:00","id":808,"links":{},"metadata":{"_buckets":{"deposit":"3cb0c1ef-9e05-424b-8422-741d3c8a4ff6"},"_deposit":{"created_by":2,"id":"808","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"808"},"status":"published"},"_oai":{"id":"oai:kutarr.kochi-tech.ac.jp:00000808","sets":["16:18"]},"author_link":["2191","2187","2189","2185","2190","2188","2186"],"item_5_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"Society for Social Management Systems Internet Journal"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Disaster prevention measures for fire in underground areas are the important subject of the city reproduction. Kajima researched and developed a new system for fire disaster prevention with water screen. Fire is zoned with water screen in this system. Then sufferers can evacuate from fire and firemen can fight with fire easily and the structures have few damage from fire.","subitem_description_type":"Abstract"}]},"item_5_publisher_36":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Society for Social Management Systems"}]},"item_5_source_id_11":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2432-552X","subitem_source_identifier_type":"ISSN"}]},"item_5_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Amano, Reiko"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Izushi, Youichi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kurioka, Hitoshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kuwana, Hideaki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tsuruda, Takashi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Suzuki, Takeshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ogawa, Yoshio"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-02-13"}],"displaytype":"detail","filename":"SMS06-121.pdf","filesize":[{"value":"315.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"SMS06-121.pdf","url":"https://kutarr.kochi-tech.ac.jp/record/808/files/SMS06-121.pdf"},"version_id":"de9e20f6-1e56-403e-bd1c-fec4f46cba9b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"water screen","subitem_subject_scheme":"Other"},{"subitem_subject":"fire prevention system","subitem_subject_scheme":"Other"},{"subitem_subject":"road tunnel","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Prevention Measures Against Fines in Road Tunnels and Water screen Fire Prevention System","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Prevention Measures Against Fines in Road Tunnels and Water screen Fire Prevention System"}]},"item_type_id":"5","owner":"2","path":["18"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-02-06"},"publish_date":"2018-02-06","publish_status":"0","recid":"808","relation_version_is_last":true,"title":["Prevention Measures Against Fines in Road Tunnels and Water screen Fire Prevention System"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-15T13:25:29.067707+00:00"}