{"created":"2023-05-15T12:35:57.537918+00:00","id":842,"links":{},"metadata":{"_buckets":{"deposit":"0f186de6-c803-4f24-a422-e9c1d64dbb69"},"_deposit":{"created_by":2,"id":"842","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"842"},"status":"published"},"_oai":{"id":"oai:kutarr.kochi-tech.ac.jp:00000842","sets":["16:19"]},"author_link":["2271","2270"],"item_5_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicVolumeNumber":"3","bibliographic_titles":[{"bibliographic_title":"Society for Social Management Systems Internet Journal"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The mechanism of the reduction in the flowability of self-compacting concrete due to pumping was clarified. Compressive and shearing force were applied to the mortar of self-compacting concrete. The authors have set up a hypothesis for the mechanism, in which the particles of the cement in the concrete can be dispersed more resulting in the larger surface area of the particles, and then the repulsing effect by the superplasticizer can be reduced. The chemical analysis was carried out to prove the hypothesis. BET surface area and the amount of adsorption of the superplasticizer were measured. Also, the compressive strength was tested. The hypothesis was proved.","subitem_description_type":"Abstract"}]},"item_5_publisher_36":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Society for Social Management Systems"}]},"item_5_source_id_11":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2432-552X","subitem_source_identifier_type":"ISSN"}]},"item_5_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Sakue, Jiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ouchi, Masahiro"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-02-13"}],"displaytype":"detail","filename":"SMS07-129.pdf","filesize":[{"value":"170.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"SMS07-129.pdf","url":"https://kutarr.kochi-tech.ac.jp/record/842/files/SMS07-129.pdf"},"version_id":"fb8f14ac-eebd-4e89-b493-dd1f91729f8b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"self-compacting concrete","subitem_subject_scheme":"Other"},{"subitem_subject":"pumping","subitem_subject_scheme":"Other"},{"subitem_subject":"external force","subitem_subject_scheme":"Other"},{"subitem_subject":"dispersion of cement particles","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Change in flowability of self-compacting concrete due to pumping","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Change in flowability of self-compacting concrete due to pumping"}]},"item_type_id":"5","owner":"2","path":["19"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-02-06"},"publish_date":"2018-02-06","publish_status":"0","recid":"842","relation_version_is_last":true,"title":["Change in flowability of self-compacting concrete due to pumping"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-05-15T13:24:27.184643+00:00"}