Item type |
学術雑誌論文 / Journal Article(1) |
公開日 |
2011-10-20 |
タイトル |
|
|
タイトル |
Noncontact Positioning Mechanism Using Pinning Effect and Electromagnets |
言語 |
|
|
言語 |
eng |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
noncontact positioning system |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
pinning effect |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
inchworm mechanism |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
著者 |
Oka, Koichi
Sakamoto, M.
Nakamura, S.
|
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
This paper describes a proposal of noncontact positioning system using pinning effect of superconductor. The proposed system consists of a superconductor, electromagnets, and actuators. The levitation force is obtained from the pinning force between a superconductor and an electromagnet and is controlled by a current switch. The pinning of electromagnet is not used for only levitation, but hold the position of the levitated object. The positioning system is moving like an inchworm system. A prototype of proposed system is introduced and some experimental results are shown. These results verify the feasibility of the proposed noncontact positioning system. |
内容記述 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM08) |
書誌情報 |
日本AEM学会誌 = Journal of the Japan Society of Applied Electromagnetics
巻 17,
号 Supplement,
p. S53-S56,
発行日 2009-09-10
|
ISSN |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
0919-4452 |
書誌レコードID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AN10457520 |
著者版フラグ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
出版者 |
|
|
出版者 |
the Japan Society of Applied Electromagnetics and Mechanics |