{"_buckets": {"deposit": "20c6da68-ed24-4255-9e27-554ecbbd28cf"}, "_deposit": {"created_by": 2, "id": "819", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "819"}, "status": "published"}, "_oai": {"id": "oai:kutarr.kochi-tech.ac.jp:00000819", "sets": ["19"]}, "author_link": ["2213", "2212", "2214"], "item_5_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicVolumeNumber": "3", "bibliographic_titles": [{"bibliographic_title": "Society for Social Management Systems Internet Journal"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A landslide gives the big loss to various structures. However, a detailed mechanism of a landslide is not understood completely. Ground based laser scanner is expected as useful measurement equipment for monitoring landslide. However, there are some problems in accurate measurement using the ground based laser scanner. Laser scanner data must be transformed into the ground coordinates using Ground Control Points (GCP). The prism is usually used for GCP. The ground coordinate of the prism is precisely measured by using GPS and Total station. However the acquisition of accurate coordinate of the prism in laser scanner data is very difficult. The error of the transformation showed maximum 10cm. This study focused on solving the problem in the geometric transformation. The accurate measurement of control points can be improved by measuring some flat surfaces. When three flat surfaces are measured, coordinates of the intersection in three planes can be calculated. This intersection can be used as a control point of the laser scanner data. This method should make accurate geometric transformation. Geometric transformation by using multi surface measurement was higher accuracy than geometric transformation using a prism. And, accuracy of geometric transformation showed less than 1cm.", "subitem_description_type": "Abstract"}]}, "item_5_publisher_36": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Society for Social Management Systems"}]}, "item_5_source_id_11": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2432-552X", "subitem_source_identifier_type": "ISSN"}]}, "item_5_version_type_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kinoshita, Kazu"}], "nameIdentifiers": [{"nameIdentifier": "2212", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miyazaki, Tomonori"}], "nameIdentifiers": [{"nameIdentifier": "2213", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takagi, Masataka"}], "nameIdentifiers": [{"nameIdentifier": "2214", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-02-13"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "SMS07-102.pdf", "filesize": [{"value": "597.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 597200.0, "url": {"label": "SMS07-102.pdf", "url": "https://kutarr.kochi-tech.ac.jp/record/819/files/SMS07-102.pdf"}, "version_id": "aca66778-6af2-4211-b55e-fbb6e2c50acf"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Monitoring Method of Landslide using Laser Scanner : Accurate Geometric Transformation by Multi Surfaces Measurement", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Monitoring Method of Landslide using Laser Scanner : Accurate Geometric Transformation by Multi Surfaces Measurement"}]}, "item_type_id": "5", "owner": "2", "path": ["19"], "permalink_uri": "http://hdl.handle.net/10173/1636", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-02-06"}, "publish_date": "2018-02-06", "publish_status": "0", "recid": "819", "relation": {}, "relation_version_is_last": true, "title": ["Monitoring Method of Landslide using Laser Scanner : Accurate Geometric Transformation by Multi Surfaces Measurement"], "weko_shared_id": -1}
  1. SSMSパブリケーション
  2. Vol.03

Monitoring Method of Landslide using Laser Scanner : Accurate Geometric Transformation by Multi Surfaces Measurement

http://hdl.handle.net/10173/1636
http://hdl.handle.net/10173/1636
3629d869-1181-49d2-a350-34cc1656dc1a
名前 / ファイル ライセンス アクション
SMS07-102.pdf SMS07-102.pdf (597.2 kB)
Item type 会議発表論文 / Conference Paper(1)
公開日 2018-02-06
タイトル
タイトル Monitoring Method of Landslide using Laser Scanner : Accurate Geometric Transformation by Multi Surfaces Measurement
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
著者 Kinoshita, Kazu

× Kinoshita, Kazu

WEKO 2212

Kinoshita, Kazu

Search repository
Miyazaki, Tomonori

× Miyazaki, Tomonori

WEKO 2213

Miyazaki, Tomonori

Search repository
Takagi, Masataka

× Takagi, Masataka

WEKO 2214

Takagi, Masataka

Search repository
抄録
内容記述タイプ Abstract
内容記述 A landslide gives the big loss to various structures. However, a detailed mechanism of a landslide is not understood completely. Ground based laser scanner is expected as useful measurement equipment for monitoring landslide. However, there are some problems in accurate measurement using the ground based laser scanner. Laser scanner data must be transformed into the ground coordinates using Ground Control Points (GCP). The prism is usually used for GCP. The ground coordinate of the prism is precisely measured by using GPS and Total station. However the acquisition of accurate coordinate of the prism in laser scanner data is very difficult. The error of the transformation showed maximum 10cm. This study focused on solving the problem in the geometric transformation. The accurate measurement of control points can be improved by measuring some flat surfaces. When three flat surfaces are measured, coordinates of the intersection in three planes can be calculated. This intersection can be used as a control point of the laser scanner data. This method should make accurate geometric transformation. Geometric transformation by using multi surface measurement was higher accuracy than geometric transformation using a prism. And, accuracy of geometric transformation showed less than 1cm.
書誌情報 Society for Social Management Systems Internet Journal

巻 3, 号 1, 発行日 2007-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 2432-552X
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
出版者
出版者 Society for Social Management Systems
戻る
0