{"_buckets": {"deposit": "4347ba26-fe71-4822-a9cb-51dad020eaf8"}, "_deposit": {"created_by": 2, "id": "1023", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "1023"}, "status": "published"}, "_oai": {"id": "oai:kutarr.kochi-tech.ac.jp:00001023", "sets": ["22"]}, "author_link": ["2727"], "item_5_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicVolumeNumber": "6", "bibliographic_titles": [{"bibliographic_title": "Society for Social Management Systems Internet Journal"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Fire resistance of tunnel structures is an important issue. Over the last 15 years there have been a number of serious underground fires in road tunnels. These fires have caused extensive loss of life and severe collateral loss to the infrastructure, aside from the tragic loss of life, the long-term financial effects to the local infrastructure, the loss of public confidence in the safe use of tunnels. This paper describes the mitigation measures for the protection of the structural elements to allow users to safely evacuate, to allow rescue personnel to enter the scene and effectively perform their required duties and to limit damage to the tunnel. Following aspects are focusing in this text, 1 Historical major tunnel fire, 2 Research for mitigation measures, 3 Time–Temperature curve for mitigation measures, 4 Basic concept of the acceptable critical temperature for concrete and steel materials, 5 Mitigation measures, and 6 Conclusion", "subitem_description_type": "Abstract"}]}, "item_5_publisher_36": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Society for Social Management Systems"}]}, "item_5_source_id_11": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2432-552X", "subitem_source_identifier_type": "ISSN"}]}, "item_5_version_type_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ota, Yoshikadzu"}], "nameIdentifiers": [{"nameIdentifier": "2727", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-02-13"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "SMS10-130.pdf", "filesize": [{"value": "983.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 983000.0, "url": {"label": "SMS10-130.pdf", "url": "https://kutarr.kochi-tech.ac.jp/record/1023/files/SMS10-130.pdf"}, "version_id": "bb5773fa-b87a-473d-925c-825916876c1f"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Tunnel fire", "subitem_subject_scheme": "Other"}, {"subitem_subject": "mitigation measures", "subitem_subject_scheme": "Other"}, {"subitem_subject": "concrete", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Universal Design Concept Of Mitigation Measures To Tunnel Structures In The Case Of Fire", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Universal Design Concept Of Mitigation Measures To Tunnel Structures In The Case Of Fire"}]}, "item_type_id": "5", "owner": "2", "path": ["22"], "permalink_uri": "http://hdl.handle.net/10173/1803", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-02-06"}, "publish_date": "2018-02-06", "publish_status": "0", "recid": "1023", "relation": {}, "relation_version_is_last": true, "title": ["Universal Design Concept Of Mitigation Measures To Tunnel Structures In The Case Of Fire"], "weko_shared_id": -1}
  1. SSMSパブリケーション
  2. Vol.06

Universal Design Concept Of Mitigation Measures To Tunnel Structures In The Case Of Fire

http://hdl.handle.net/10173/1803
http://hdl.handle.net/10173/1803
0badcae0-6129-4d71-8e15-739d779ab7cc
名前 / ファイル ライセンス アクション
SMS10-130.pdf SMS10-130.pdf (983.0 kB)
Item type 会議発表論文 / Conference Paper(1)
公開日 2018-02-06
タイトル
タイトル Universal Design Concept Of Mitigation Measures To Tunnel Structures In The Case Of Fire
言語
言語 eng
キーワード
主題Scheme Other
主題 Tunnel fire
キーワード
主題Scheme Other
主題 mitigation measures
キーワード
主題Scheme Other
主題 concrete
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
著者 Ota, Yoshikadzu

× Ota, Yoshikadzu

WEKO 2727

Ota, Yoshikadzu

Search repository
抄録
内容記述タイプ Abstract
内容記述 Fire resistance of tunnel structures is an important issue. Over the last 15 years there have been a number of serious underground fires in road tunnels. These fires have caused extensive loss of life and severe collateral loss to the infrastructure, aside from the tragic loss of life, the long-term financial effects to the local infrastructure, the loss of public confidence in the safe use of tunnels. This paper describes the mitigation measures for the protection of the structural elements to allow users to safely evacuate, to allow rescue personnel to enter the scene and effectively perform their required duties and to limit damage to the tunnel. Following aspects are focusing in this text, 1 Historical major tunnel fire, 2 Research for mitigation measures, 3 Time–Temperature curve for mitigation measures, 4 Basic concept of the acceptable critical temperature for concrete and steel materials, 5 Mitigation measures, and 6 Conclusion
書誌情報 Society for Social Management Systems Internet Journal

巻 6, 号 1, 発行日 2010-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 2432-552X
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
出版者
出版者 Society for Social Management Systems
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 13:18:37.268750
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3